製品詳細
試験電圧:
3500V
ジャケット:
自由の低い煙ハロゲン
サンプル:
Freee
保証:
2年
色:
オレンジ
動作温度:
90度
ハイライト: 

low smoke zero halogen wire

,

lszh power cable

支払いと配送条件
最小注文数量
300 m
価格
USD 0.12-2.97/M
パッケージの詳細
ドラム
受渡し時間
7日
支払条件
LC、T/T
供給の能力
86000KM/Day
製品説明

LSOH WDZA-YJY-0.6/1KV 3x2.5SQMM Building lighting System China Best Manufacturer

 

Conductor: Class 1/2 annealed bare copper solid or strands. This wires are formed into final conductor in the stranding machines under strict quality surveillance.

 

Insulation: Cross linked polyethylene compound or PVC is insulated over the conductors by extrusion process.The raw materials and thicknesses of Insulation are maintained as per standards and conform to IEC60502/BS7870 Standards as the case may be.

 

XLPE:Insulated Power Cable are identified either by colour or by numbers as follows:
No. of cores Identification
Old Colour coding New Colour coding as per requirement

 

Armour : When armouring is required, the armour consists of single layer of galvanised steel wires/galvanized steel tapes.
The armour is applied helically as per standards.
Single core cables are armoured with Aluminium Wires or Copper wires based on requirement.

 

Outer sheath : Standard cables are manufactured with Extruded black PVC. Outersheath is embossed or printed with the information required by relevant standards.
Special FR, FRLS, FRRT, LSF, MDPE compounds are used for outersheathing of cables, to suit customer’s specific requirements.

 

Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 61034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request

 

Technical data

Rated voltage: 0.6-1kV

Max. Conductor Temp.:normal (90℃), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C

Min. Bending Radius: single core cable 20(d+D)±5% ,Multi-core cable 15(d+D)±5%